[[Category:Simplified system design]]
 
[[Category:Simplified system design]]
The size of the [[PV module|PV source]], which is determined based upon the [[Simplified load evaluation|simplified load evaluation]] and [[Simplified weather and solar resource evaluation|simplified weather and solar resource evaluation]] will determine the necessary size of the [[Charge controller|charge controller]]. The charge controller must be selected at the same time as the PV source as the [[Charge controller#Charge controller types|charge controller type]] - PWM or MPPT - will also determine the possible configurations of PV modules.  
+
<languages />
 +
<translate>
 +
<!--T:1-->
 +
The size of the [[Special:MyLanguage/PV module|PV source]], which is determined based upon the [[Special:MyLanguage/Simplified load evaluation|simplified load evaluation]] and [[Special:MyLanguage/Simplified weather and solar resource evaluation|simplified weather and solar resource evaluation]] will determine the necessary size of the [[Special:MyLanguage/Charge controller|charge controller]]. The charge controller must be selected at the same time as the PV source as the [[Special:MyLanguage/Charge controller#Charge controller types|charge controller type]] - PWM or MPPT - will also determine the possible configurations of PV modules.  
  
In this phase of the design process, more than in any other phase, it is necessary to explore different designs using [[PV module|PV module]], [[Series and parallel|series and parallel wiring configurations]], and [[Charge controller|charge controllers]] in order to achieve the highest performance at the lowest cost possible. This phase may have to be performed several times.
+
<!--T:2-->
 +
In this phase of the design process, more than in any other phase, it is necessary to explore different designs using [[Special:MyLanguage/PV module|PV module]], [[Special:MyLanguage/Series and parallel connections|series and parallel wiring configurations]], and [[Special:MyLanguage/Charge controller|charge controllers]] in order to achieve the highest performance at the lowest cost possible. This phase may have to be performed several times.
  
An off-grid PV system that depends upon the PV as its single charging source requires an array that is sufficiently sized to be able to generate sufficient energy to both meet the energy needs of the users and to recharge the [[Energy storage|energy storage system]] under less-than-ideal conditions. Any sizing decisions should therefore lean towards an oversized PV source.
+
<!--T:3-->
 +
An off-grid PV system that depends upon the PV as its single charging source requires an PV source that is sufficiently sized to be able to generate sufficient energy to both meet the energy needs of the users and to recharge the [[Special:MyLanguage/Energy storage|energy storage system]] under less-than-ideal conditions. Any sizing decisions should therefore lean towards an larger PV source.
  
 +
<!--T:4-->
 
'''Assumptions:'''
 
'''Assumptions:'''
*The system is designed for a non-critical application, meaning that users can/will adjust their energy needs according to the weather.
+
*The system will be used for a non-critical application, meaning that users can adjust their energy needs according to the weather.
*The [[PV module|PV source]] will have little to no shading from trees or mountains.
+
*The [[Special:MyLanguage/PV module|PV source]] will have little to no shading from trees or mountains.
*The [[PV module|PV source]] will be cleaned at least every two months or as often as it becomes heavily soiled.
+
*The [[Special:MyLanguage/PV module|PV source]] will be cleaned at least every two months or as often as it becomes heavily soiled.
*The temperature does not regularly rise above 40°C.
 
 
*A lead acid battery will be used.
 
*A lead acid battery will be used.
*See [[#Notes/references|Notes/references]] for more details.
+
*See Notes/references section below for detailed parameters used in this process.
  
====Step 1: Select minimum PV source size====
+
====Step 1: Determine minimum PV source size==== <!--T:5-->
The proper value should be chosen by using the [[Simplified load evaluation|Total average daily energy demand]] and the [[Simplified weather and solar resource evaluation|Minimum monthly solar resource]].  
+
A value should be chosen by using the [[Special:MyLanguage/Simplified load evaluation|Total daily Wh required]] and the [[Special:MyLanguage/Simplified weather and solar resource evaluation|Minimum monthly solar resource]].<br />
[[File:MinimumPVchart210119.png|frameless]]
+
[[File:MinimumPVchart2101192.png|frameless]]
  
====Step 2: Adjust minimum PV source size for maximum temperature===
+
====Step 2: Adjust minimum PV source size for maximum temperature==== <!--T:6-->
  
 +
<!--T:7-->
 
{| class="wikitable" border=1
 
{| class="wikitable" border=1
 
!Temperature
 
!Temperature
!Maximum temperature
 
 
!Temperature adustement factor
 
!Temperature adustement factor
 
|-
 
|-
Line 41: Line 46:
 
|}
 
|}
  
====Step 5: Determine charge controller type====
+
<!--T:8-->
There are two different charge controller types - pulse width modulation (PWM) and maximum power point tracking (MPPT) - each of which has advantages and disadvantages that are are detailed in [[Charge controller#Charge controller types|Charge controller types]]. Two separate designs may be performed with each type of charge controller to determine the best system design. The current and voltage rating of the charge controller will be determined when in either [[PWM charge controller sizing and selection]] or [[MPPT charge controller sizing and selection]].
+
{| class="wikitable" border=1 style="width: 80%;"
 +
! style="width: 20%"|Temperature adjusted minimum PV source size
 +
! style="text-align:left;"| = Minimum PV source size (Step 1) ÷ Temperature adjustement factor
 +
|}
 +
 
 +
====Step 3: Determine charge controller type==== <!--T:9-->
 +
There are two different charge controller types - pulse width modulation (PWM) and maximum power point tracking (MPPT) - each of which has advantages and disadvantages that are are detailed in [[Special:MyLanguage/Charge controller#Charge controller types|Charge controller types]]. Two separate designs may be performed with each type of charge controller to determine the best system design. The current and voltage rating of the charge controller will be determined during the [[Special:MyLanguage/Simplified PWM charge controller sizing and selection|Simplified PWM charge controller sizing and selection]] or [[Special:MyLanguage/Simplified MPPT charge controller sizing and selection|Simplified PWM charge controller sizing and selection]] design process.
  
 +
<!--T:10-->
 
:'''PWM:'''<br />
 
:'''PWM:'''<br />
:The PV source must be configured to operate at the charging voltage of the [[Energy storage|energy storage system]] and below the maximum PV source current rating of the charge controller.
+
:The PV source must be configured to operate at the charging voltage of the [[Special:MyLanguage/Energy storage|energy storage system]] and below the maximum PV source current rating of the charge controller.
 
:*Nominal system voltage: 12V, 24V, 48V.  
 
:*Nominal system voltage: 12V, 24V, 48V.  
 
:*Maximum PV source current: 6A-60A
 
:*Maximum PV source current: 6A-60A
  
 +
<!--T:11-->
 
:'''MPPT:'''<br />
 
:'''MPPT:'''<br />
 
:The PV source must be configured to operate below the maximum PV source voltage rating of the charge controller, above the minimum PV source voltage based upon the maximum charging , and below the maximum PV source current rating of the charge controller.  
 
:The PV source must be configured to operate below the maximum PV source voltage rating of the charge controller, above the minimum PV source voltage based upon the maximum charging , and below the maximum PV source current rating of the charge controller.  
Line 56: Line 69:
 
:*Maximum PV source current: up to 100A+
 
:*Maximum PV source current: up to 100A+
  
==Notes/references==
+
==Notes/references== <!--T:12-->
 
*Location max temp = 40°C
 
*Location max temp = 40°C
 
*Mounting system temperature adder = 25°C
 
*Mounting system temperature adder = 25°C
Line 68: Line 81:
 
*Charge controller efficiency parameter = 0.98
 
*Charge controller efficiency parameter = 0.98
 
*Final total loss factor = 0.5
 
*Final total loss factor = 0.5
 +
</translate>

Latest revision as of 16:44, 6 April 2021

Other languages:
English • ‎español

The size of the PV source, which is determined based upon the simplified load evaluation and simplified weather and solar resource evaluation will determine the necessary size of the charge controller. The charge controller must be selected at the same time as the PV source as the charge controller type - PWM or MPPT - will also determine the possible configurations of PV modules.

In this phase of the design process, more than in any other phase, it is necessary to explore different designs using PV module, series and parallel wiring configurations, and charge controllers in order to achieve the highest performance at the lowest cost possible. This phase may have to be performed several times.

An off-grid PV system that depends upon the PV as its single charging source requires an PV source that is sufficiently sized to be able to generate sufficient energy to both meet the energy needs of the users and to recharge the energy storage system under less-than-ideal conditions. Any sizing decisions should therefore lean towards an larger PV source.

Assumptions:

  • The system will be used for a non-critical application, meaning that users can adjust their energy needs according to the weather.
  • The PV source will have little to no shading from trees or mountains.
  • The PV source will be cleaned at least every two months or as often as it becomes heavily soiled.
  • A lead acid battery will be used.
  • See Notes/references section below for detailed parameters used in this process.

Step 1: Determine minimum PV source size

A value should be chosen by using the Total daily Wh required and the Minimum monthly solar resource.
MinimumPVchart2101192.png

Step 2: Adjust minimum PV source size for maximum temperature

Temperature Temperature adustement factor
25°C 1.00
30°C .97
35°C .94
40°C .91
45°C .88
Temperature adjusted minimum PV source size = Minimum PV source size (Step 1) ÷ Temperature adjustement factor

Step 3: Determine charge controller type

There are two different charge controller types - pulse width modulation (PWM) and maximum power point tracking (MPPT) - each of which has advantages and disadvantages that are are detailed in Charge controller types. Two separate designs may be performed with each type of charge controller to determine the best system design. The current and voltage rating of the charge controller will be determined during the Simplified PWM charge controller sizing and selection or Simplified PWM charge controller sizing and selection design process.

PWM:
The PV source must be configured to operate at the charging voltage of the energy storage system and below the maximum PV source current rating of the charge controller.
  • Nominal system voltage: 12V, 24V, 48V.
  • Maximum PV source current: 6A-60A
MPPT:
The PV source must be configured to operate below the maximum PV source voltage rating of the charge controller, above the minimum PV source voltage based upon the maximum charging , and below the maximum PV source current rating of the charge controller.
  • Nominal system voltage: 12V, 24V, 48V
  • Maximum PV source voltage: varies up to 600V
  • Minimum PV source voltage: depends upon nominal voltage and charge controller type
  • Maximum PV source current: up to 100A+

Notes/references

  • Location max temp = 40°C
  • Mounting system temperature adder = 25°C
  • Temperature power loss factor = -0.48%/°C
  • Module degradation parameter = 0.9
  • Shading loss parameter = 0.95
  • Soiling loss parameter = 0.95
  • Wiring loss parameter = 0.96
  • Module mismatch parameter = 0.98
  • Energy storage efficiency parameter = 0.75
  • Charge controller efficiency parameter = 0.98
  • Final total loss factor = 0.5